Abstract
The aim of the presented study is to evaluate the impact of water supply tanks that cooperate with the water distribution system on the energy costs of water supply pumping stations. Network tanks accumulate a supply of water at night with low water intakes, making it possible to design a smaller pumping station. To achieve the above goal, a model of the water distribution system of the city of Krosno was prepared and numerical simulations were carried out using the EPANET program for various variants with an additional water tank at various locations. For each variant, the daily cost of pumping station operation, as well as the average and maximum electricity consumption, were read. A comparison of the results shows a positive impact on the reduction in the energy costs of water pumping stations.
References
Amirabdollahian, M., & Mokhtari, M. (2015). Optimal Design of pumped water distribution networks with storage under uncertain hydraulic constraints. Water Resources Management, 29, 2637-2653. https://doi.org/10.1007/s11269-015-0961-7
Barán, B., Von Lücken, C., & Sotelo, A. (2005). Multi-objective pump scheduling optimisation using evolutionary strategies. Advances in Engineering Software, 36(1), 39-47. https://doi.org/10.1016/j.advengsoft.2004.03.012
Bene, J. G., & Hős, C. J. (2012). Finding least-cost pump schedules for reservoir filling with a variable speed pump. Journal of Water Resources Planning and Management, 138(6), 682-686. https://doi.org/10.1061/(ASCE)WR.1943-5452.0000213
Blinco, L. J., Simpson, A. R., Lambert, M. F., Auricht, C. A., Hurr, N. E., Tiggemann, S. M., & Marchi, A. (2014). Genetic algorithm optimization of operational costs and greenhouse gas emissions for water distribution systems. Procedia Engineering, 89, 509-516. https://doi.org/10.1016/j.proeng.2014.11.246
Bonvin, G., Demassey, S., Le Pape, C., Maizi, N., Mazauric, V., & Samperio, A. (2016) A convex mathematical program for pump scheduling in a class of branched water networks. Applied Energy, 185, 1702–1711. https://doi.org/10.1016/j.apenergy.2015.12.090
Celi, C. L., Iglesias-Rey, P. L., & Solano, F. M. (2017). Energy optimization of supplied flows from multiple pumping stations in water distributions networks. Procedia Engineering, 186, 93-100. https://doi.org/10.1016/j.proeng.2017.03.214
Chen, W., Tao, T., Zhou, A., Zhang, L., Liao, L., Wu, X., Yang, K., Chenxiu, C., Zhang, T.C. & Li, Z. (2021). Genetic optimization toward operation of water intake-supply pump stations system. Journal of Cleaner Production, 279, 123573. https://doi.org/10.1016/j.jclepro.2020.123573
Cimorelli, L., D’Aniello, A., & Cozzolino, L. (2020). Boosting genetic algorithm performance in pump scheduling problems with a novel decision-variable representation. Journal of Water Resources Planning and Management, 146(5). https://doi.org/10.1061/(asce)wr.1943-5452.0001198
da Costa Bortoni, E., de Almeida, R. A., & Viana, A. N. C. (2008). Optimization of parallel variable-speed-driven centrifugal pumps operation. Energy Efficiency, 1(3), 167-173. https://doi.org/10.1007/s12053-008-9010-1
Dadar, S., Durin, B., Alamatian, E., & Plantak, L. (2021). Impact of the Pumping Regime on Electricity Cost Savings in Urban Water Supply System. WATER, 13(9), 1141. https://doi.org/10.3390/w13091141
Fang, H. E., Zhang, J., & Gao, J. L. (2010). Optimal operation of multi-storage tank multi-source system based on storage policy. Journal of Zhejiang University-SCIENCE A, 11(8), 571-579. https://doi.org/10.1631/jzus.A0900784
Fu, H., Wang, J. J., Yuan, W. N., Zhang, C. S., Li, H., Feng, Y., Zhao, M., Wang, T., & Huang, P. P. (2016). Application of hydraulic model in optimal operation of water supply pumping station. Paper presented at the 2nd International Conference on Advances in Mechanical Engineering and Industrial Informatics (AMEII), Hangzhou, PEOPLES R CHINA. https://doi.org/10.2991/ameii-16.2016.253
Guerrero-Angulo, J. O., Arreguin-Cortes, F. I., & Felix-Higuera, J. L. (2006). Design of drinking water networks with several tanks and water supply sources. Ingenieria Hidraulica En Mexico, 21(4), 145-162. https://www.scribd.com/document/397537471/DISENO-DE-REDES-DE-AGUA-Y-ALCANTARILLADO (in Spanish).
Hallmann, C., & Suhl, L. (2016). Optimizing water tanks in water distribution systems by combining network reduction, mathematical optimization and hydraulic simulation. Or Spectrum, 38(3), 577-595. https://doi.org/10.1007/s00291-015-0403-1
Jędral, W. (2007). Efektywność energetyczna pomp i instalacji pompowych. Krajowa Agencja Poszanowania Energii SA. (in Polish).
Jia, M. X., Zhang, J. L., & Xu, Y. M. (2020). Optimization Design of Industrial Water Supply Pump Station Considering the Influence of Atmospheric Temperature on Operation Cost. Ieee Access, 8, 161702-161712. https://doi.org/10.1109/access.2020.3021304
Lingireddy, S., & Wood, D. J. (1998). Improved operation of water distribution systems using variable-speed pumps. Journal of Energy Engineering, 124(3), 90-103. https://doi.org/10.1061/(ASCE)0733-9402(1998)124:3(90)
López-Ibáñez, M., Prasad, T. D., & Paechter, B. (2008). Ant colony optimization for optimal control of pumps in water distribution networks. Journal of Water Resources Planning and Management, 134(4), 337-346. https://doi.org/10.1061/(asce)0733-9496(2008)134:4(337)
Luna, T., Ribau, J., Figueiredo, D., & Alves, R. (2019). Improving energy efficiency in water supply systems with pump scheduling optimization. Journal of Cleaner Production, 213, 342-356. https://doi.org/10.1016/j.jclepro.2018.12.190
Makaremi, Y., Haghighi, A., & Ghafouri, H. R. (2017). Optimization of pump scheduling program in water supply systems using a self-adaptive NSGA-II; a review of theory to real application. Water Resources Management, 31, 1283-1304. https://doi.org/10.1007/s11269-017-1577-x
Mambretti, S. (2011). Optimization of the pumping station of the Milano water supply network with Genetic Algorithms. WIT Transactions on Ecology and the Environment, 143, 185-194. https://doi.org/10.2495/ESUS110161
PGE Polska Grupa Energetyczna (2025). Maksymalne ceny prądu dla jednostek samorządu terytorialnego i podmiotów użyteczności publicznej. https://www.gkpge.pl/dla-firm/maksymalna-cena-pradu-w-2025-r (in Polish).
Prasad, T. D. (2010). Design of pumped water distribution networks with storage. Journal of Water Resources Planning and Management, 136(1), 129-132. https://doi.org/10.1061/(ASCE)0733-9496(2010)136:1(129)
Reis, A. L., Lopes, M. A., Andrade-Campos, A., & Antunes, C. H. (2023). A review of operational control strategies in water supply systems for energy and cost efficiency. Renewable and Sustainable Energy Reviews, 175, 113140. https://doi.org/10.1016/j.rser.2022.113140
Rossman, L. A. (2000). EPANET2 Users Manual National Risk Management Research Laboratory, US Environmental Protection Agency. https://www.researchgate.net/publication/221936237_Epanet_2_users_manual
Studziński, A., Boryczko, K., Kamuda, K., Piegdoń, I., Pietrucha – Urbanik, K., Szpak, D. Stręk, M., & Żywiec, J. (2022). Podsumowanie realizacji projektu przedstawiające dobre praktyki w zakresie możliwym do wykorzystania w innych miastach. https://www.popt.gov.pl/media/113462/Zaangazowani_w_eKrosno.pdf (in Polish).
Swietochowska, M., & Bartkowska, I. (2022). Optimization of Energy Consumption in the Pumping Station Supplying Two Zones of the Water Supply System. Energies, 15(1), 310. https://doi.org/10.3390/en15010310
Trifunovic, N., Abunada, M., Babel, M., & Kennedy, M. (2015). The role of balancing tanks in optimal design of water distribution networks. Journal of Water Supply Research and Technology-Aqua, 64(5), 610-628. https://doi.org/10.2166/aqua.2014.043
Viholainen, J., Tamminen, J., Ahonen, T., Ahola, J., Vakkilainen, E., & Soukka, R. (2013). Energy-efficient control strategy for variable speed-driven parallel pumping systems. Energy Efficiency, 6, 495-509. https://doi.org/10.1007/s12053-012-9188-0
Yin, M. T., Andrews, J. F., & Stenstrom, M. K. (1996). Optimum simulation and control of fixed-speed pumping stations. Journal of Environmental Engineering, 122(3), 205-211. https://doi.org/10.1061/(ASCE)0733-9372(1996)122:3(205)
Zheng, G. L., & Huang, Q. (2016). Energy Optimization Study of Rural Deep Well Two-Stage Water Supply Pumping Station. Ieee Transactions on Control Systems Technology, 24(4), 1308-1316. doi:10.1109/tcst.2015.2498140

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Copyright (c) 2026 Economics and Environment